Service Entrance Generator Panel

 

 Press Release

June 30, 1998
Generator Panel

Download Additional Product Information

Brochure
Size: 174KB
Format : PDF
Application Note:
Stand-By Generator Panels

Size: 57KB
Format : PDF
Generator Panels
Powerpoint Presentation

Size: 869KB
Format : PPT

Right Click and Choose Save Target As... to Save.


Main Lugs Generator Panel

You can be left without electrical power for a variety of reasons.ice storms, snow storms, thunderstorms, fallen trees, floods.the list goes on. But with critical loads such as furnaces, water pumps, lights and refrigerators SAFELY connected to a stand-by power source like an electrical generator, dangerous situations can be avoided.

Note: for a closeup picture of mechanical interlock, place mouse over picture

The Federal Pioneer Stab-lok® Generator Panel allows customers to be permanently connected to critical loads so they may be fed from either the utility supply or from a stand-by generator at any time.

The INNOVATIVE design of the Stab-lok Generator Panel ensures that only one source of power will feed the critical circuits at any given time. Innovation in the design also ensures 100% quality control over the installation of the main breakers in the factory.

With a Stab-lok Generator Panel installed SAFETY is provided to the customer, their generator, appliances and utility workmen.

Catalogue Number

Amperes

Circuits

GP3P30-20

30

20

GP3P60-20

60

20

Note: It is recommended that this product be used with a generator which has a bonded neutral. Refer to the nameplate data on the generator which will state either BONDED NEUTRAL or alternatively UNBONDED NEUTRAL.

Installation CONVENIENCE is provided to the installer by offering one compact transfer switch and panel package which uses STAB-LOK® circuit breakers. Also, after installation the user enjoys the convenience of switching between electrical sources in a matter of seconds.

CONVENIENCE - USER
All critical loads are permanently connected into the building's electrical system. Transferring the critical loads from utility supply to generator supply is simply a matter of turning off one breaker and turning on a second. Regardless of the length of the power outage, a few minutes to weeks at a time, back-up power is readily available.

CONVENIENCE - INSTALLER
The panel consists of a transfer mechanism and a loadcentre in one compact package. The panel uses industry recognized STAB-LOK® breakers which are known for their reliable service and are readily available at most electrical wholesale and retail outlets.

SAFETY - USER
The installation will be a permanent and integral part of the building electrical system.  Proven circuit breaker protection, using STAB-LOK® breakers on the critical loads prevents circuits from being overloaded. Overloaded circuits cause most residential fires. Once the installation is complete there is no need to perform any electrical wiring in the event of a power outage. With available electrical power there will be no need to use alternative cooking and heating methods which could provide additional fire and air quality risks to the homeowner.

SAFETY - EQUIPMENT
Mechanically interlocked main breakers ensure only one source can be providing power at any given time. This prevents damage to the generator and to any electronics and appliances in the residence.

SAFETY - HYDRO UTILITY WORKERS
Mechanically interlocked main circuit breakers ensure that when the critical loads are fed from a generator, that the loads are isolated from the utility system and there is no danger to the workmen down the road.

INNOVATIVE DESIGN
The main breakers use a unique 3-pole design to switch both the line and neutral conductors simultaneously. This is the recommended switching design when connecting a generator with a bonded neutral (refer to the generator nameplate to determine if it has a bonded or unbonded neutral). The main breakers are specially designed to ensure that they will be properly installed in the factory 100% of the time.  The main breakers have an interrupting rating of 10KAIC. This panel provides short circuit fault protection to the critical loads, up to 10,000A, regardless of the protection level of the existing installation. The main breakers are mechanically interlocked to prevent both breakers from being turned on at the same time. This prevents damage to the generator, appliances and electronics.  The mechanical interlock is an integral component of the main breaker assembly and cannot be inadvertently removed in the field which would allow both breaker to be turned on at the same time.